Skip to main navigation Skip to search Skip to main content

Centrifugal microfluidics for rapid target analyte quantification in airborne bioaerosols

  • Soongwon Cho
  • , Michael Brothers
  • , Ziyu Chen
  • , Samet Şahin
  • , Yirui Xiong
  • , Nicole Schaeublin
  • , Doug Adkins
  • , Charles Call
  • , Anthony Banks
  • , Steve S. Kim
  • , John A. Rogers

Research output: Contribution to journal › Article › peer-review

Abstract

Bioaerosols comprise an array of airborne particles that can be benign, contain irritants (i.e., allergens), or disseminate pathogens. Current fieldable devices are incapable of discriminating between benign bioaerosols and pathogenic bioaerosols. Thus, rapid on-site detection and identification at the point of exposure of the components comprising bioaerosols is critical to assess health risks; elimination of both false positives and false negatives is essential to ensure that the correct countermeasures are deployed. The sandwich enzyme-linked immunosorbent assay (sandwich ELISA) remains a gold standard technique for accurate, sensitive detection of proteins, bacteria, and viruses. ELISAs require recognition of the target by two biorecognition elements (BREs) and thus effectively eliminate false positives. The sandwich ELISA, however, suffers from laborious manual processes, which severely impacts its utility in point-of-care (POC). Centrifugal microfluidics offers an automated solution to execute multi-step ELISAs. Here, we introduce a centrifugal microfluidic device that operates based on passive capillary and siphon valving networks to detect human serum albumin (HSA) concentrations in collected bioaerosol samples. We investigate key aspects for minimizing the assay operation time by investigating siphon valve mechanisms, co-incubation time for HSA with a capture antibody and detection antibody conjugated with streptavidin-horse radish peroxidase (strep-HRP), and incubation time for tetramethylbenzidine with strep-HRP for electrochemical amperometric detection. The fully integrated device quantifies HSA concentrations in 15 minutes based on a small sample volume of 12.5 μL. Using the device, we successfully quantify HSA concentrations in bioaerosol samples and obtain results similar to standard 96 well plate-based ELISA.

Original languageEnglish
Pages (from-to)4429-4442
Number of pages14
JournalLab on a Chip
Volume26
Issue number16
DOIs
Publication statusPublished - 5 Jun 2026

Bibliographical note

Publisher Copyright:
This journal is © The Royal Society of Chemistry, 2026.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Centrifugal microfluidics for rapid target analyte quantification in airborne bioaerosols'. Together they form a unique fingerprint.

Cite this