Skip to main navigation Skip to search Skip to main content

Cyclic loading test for walls of aspect ratio 1.0 and 0.5 with grade 550 MPa (80 ksi) shear reinforcing bars

Research output: Contribution to journalArticlepeer-review

66 Citations (Scopus)

Abstract

In the shear design of massive walls in nuclear power plants, high-strength reinforcing bars need to be employed to enhance the constructibility and economy of the walls. In the present study, walls with aspect ratios of 1.0 and 0.5 were tested under cyclic lateral loading to investigate the effect of 550 MPa (80 ksi) reinforcing bars on the shear strength of squat walls. The test parameters included the grade of shear reinforcement, the failure mode, and the presence of boundary hoops. The ratios of the test shear strength to ACI 349 prediction (that is, safety margins) were 1.54 to 1.90 and 1.11 to 1.38 for the general and seismic provisions, respectively. The test results of walls with 550 MPa (80 ksi) reinforcing bars were comparable to those of walls with 420 MPa (60 ksi) reinforcing bars for all three evaluations: failure mode, safety margin, and average crack width.

Original languageEnglish
Pages (from-to)969-982
Number of pages14
JournalACI Structural Journal
Volume114
Issue number4
DOIs
Publication statusPublished - 1 Jul 2017

Bibliographical note

Publisher Copyright:
© 2017, American Concrete Institute. All rights reserved.

Keywords

  • Cyclic loading
  • High-strength reinforcing bars
  • Reinforcing bar ratio
  • Shear strength
  • Squat shear walls

Fingerprint

Dive into the research topics of 'Cyclic loading test for walls of aspect ratio 1.0 and 0.5 with grade 550 MPa (80 ksi) shear reinforcing bars'. Together they form a unique fingerprint.

Cite this