Development of a Simple and Validated LC–MS/MS Method for Quantitative Determination of Ketotifen in Beagle Dog Plasma and Its Application to Bioequivalence Study of Ketotifen Syrup Dosage Form

Eunseo Song, Wang Seob Shim, Doowon Choi, Yuna Song, Hyeong Geun Jo, Soobok Lee, Suk Han Jung, Yeo Jin Choi, Kyung Tae Lee

Research output: Contribution to journalArticlepeer-review

Abstract

A highly accurate, precise, and simple liquid chromatography-tandem mass spectrometry (LC–MS/MS) method for ketotifen (KTF) estimation from Beagle dog plasma was developed and validated, with ketotifen-d3 (KTF-d3) as the internal standard (IS). KTF and IS were detected on an API 4000 mass spectrometer in multiple reaction monitoring (MRM) mode in electrospray ionization (ESI) positive ionization mode. The transitions were monitored at m/z 310.2 → 96.0 for KTF and m/z 313.2 → 99.1 for IS. KTF and IS were extracted from plasma using liquid-liquid extraction with methyl tertiary-butyl ether and then analyzed for 3 min with extracted samples (7 µL) into the LC–MS/MS system. Analytes were separated on a Luna® Hilic column (50 × 2.0 mm i.d., 3 μm) using the Nexera X2 HPLC. The mobile phase A consisted of 10 mmol/L ammonium formate (pH 3.0), while mobile phase B consisted of 0.05% formic acid in acetonitrile. The ratio of mobile phase was 5:95 (v/v) at a flow rate of 0.2 mL/min. The method has been thoroughly validated in accordance with the bioanalytical method validation guidelines established by the Ministry of Food and Drug Safety in Korea and the U.S. Food and Drug Administration, addressing selectivity, lower limit of quantification, linearity, carryover, precision, accuracy, recovery, matrix effect, and stability. The developed LC–MS/MS method was effectively utilized for the bioequivalence assessment of ketotifen in Beagle dog plasma following the oral administration of ketotifen syrup.

Original languageEnglish
Article number4505
JournalMolecules
Volume29
Issue number18
DOIs
Publication statusPublished - Sept 2024

Bibliographical note

Publisher Copyright:
© 2024 by the authors.

Keywords

  • Beagle dog plasma
  • LC–MS/MS
  • bioanalytical method validation
  • bioequivalence
  • ketotifen
  • syrup