Skip to main navigation Skip to search Skip to main content

Development of corroded gas pipeline assessment program based on limit load solution

  • Choon Kim Jong
  • , Jun Shim Do
  • , Ok Yoon Kang
  • , Boong Choi Jae
  • , Suk Chang Yoon
  • , Jin Kim Young
  • , Chun Choi Song
  • , Sik Kim Woo

Research output: Contribution to journalArticlepeer-review

3 Citations (Scopus)

Abstract

Pipelines have the highest capacity and are the safest and the least environmentally disruptive means for transmitting gas or oil. Recently, failures due to corrosion defects have become a major concern in maintaining pipeline integrity. A number of solutions have been developed for the assessment of remaining strength of corroded pipelines. In this paper, a Fitness-For-Purpose (FFP) type limit load solution for corroded city gas pipelines is proposed. For this purpose, a series of burst tests with various types of machined defects were performed. Finite element simulations were carried out to derive an appropriate failure criterion. Based on such solution along with existing solutions, an integrity evaluation program for corroded city gas pipeline, COPAP-CITY, has been developed.

Original languageEnglish
Pages (from-to)47-52
Number of pages6
JournalKey Engineering Materials
Volume297-300 I
Publication statusPublished - 2005

Keywords

  • City gas pipeline
  • Corrosion defect
  • Finite element analysis
  • Fitness-for-purpose

Fingerprint

Dive into the research topics of 'Development of corroded gas pipeline assessment program based on limit load solution'. Together they form a unique fingerprint.

Cite this