TY - JOUR
T1 - Dicarboxylate-containing and fully substituted ferrocene with rapid dissolvability, high solubility, good stability, and moderate formal potential for mediated electrochemical detection
AU - Lee, Woohyeong
AU - Bhatia, Aman
AU - Nandhakumar, Ponnusamy
AU - Kim, Gyeongho
AU - Joo, Jung Min
AU - Yang, Haesik
N1 - Publisher Copyright:
© 2023 The Royal Society of Chemistry.
PY - 2023/2/17
Y1 - 2023/2/17
N2 - An electron mediator with rapid dissolvability and high solubility in aqueous electrolyte solutions is essential for point-of-care testing based on mediated electrochemical detection. However, most ferrocenyl (Fc) compounds have slow dissolvability and poor solubility owing to high hydrophobicity of the Fc backbone. Moreover, many Fc compounds have poor stability and nonoptimal formal potential (). Herein, we present an Fc compound, Fc8m2c, which exhibits rapid dissolvability, high solubility, good stability, and moderate along with its high electron-mediation rate. The of Fc8m2c (0.17 V vs. Ag/AgCl) is tuned by two electron-withdrawing acyl substituents and eight electron-donating methyl substituents. Two pendant carboxylate groups of Fc8m2c allow for rapid dissolvability and high solubility (0.63 M in water), whereas full substitution in its two cyclopentadienyl ligands facilitates good chemical stability against decomposition in the presence of dissolved O2 and ambient light. A moderate enables the application of a potential of 0.07 V at which electrochemical background currents are low and also contributes toward resisting the decomposition of both Fc8m2c and Fc8m2c+. Fc8m2c provides a high electron-mediation rate constant (2.4 × 106 M−1 s−1) in glucose detection using glucose dehydrogenase. When Fc8m2c is applied to a glucose sensor, the calculated detection limit is ∼0.1 mM with a measurement period of 5 s. Considering that the normal concentration of glucose in serum is between 3.9 and 6.6 mM, the detection limit is sufficiently low. These results show that Fc8m2c is an excellent electron-mediator candidate for sensitive and rapid glucose detection.
AB - An electron mediator with rapid dissolvability and high solubility in aqueous electrolyte solutions is essential for point-of-care testing based on mediated electrochemical detection. However, most ferrocenyl (Fc) compounds have slow dissolvability and poor solubility owing to high hydrophobicity of the Fc backbone. Moreover, many Fc compounds have poor stability and nonoptimal formal potential (). Herein, we present an Fc compound, Fc8m2c, which exhibits rapid dissolvability, high solubility, good stability, and moderate along with its high electron-mediation rate. The of Fc8m2c (0.17 V vs. Ag/AgCl) is tuned by two electron-withdrawing acyl substituents and eight electron-donating methyl substituents. Two pendant carboxylate groups of Fc8m2c allow for rapid dissolvability and high solubility (0.63 M in water), whereas full substitution in its two cyclopentadienyl ligands facilitates good chemical stability against decomposition in the presence of dissolved O2 and ambient light. A moderate enables the application of a potential of 0.07 V at which electrochemical background currents are low and also contributes toward resisting the decomposition of both Fc8m2c and Fc8m2c+. Fc8m2c provides a high electron-mediation rate constant (2.4 × 106 M−1 s−1) in glucose detection using glucose dehydrogenase. When Fc8m2c is applied to a glucose sensor, the calculated detection limit is ∼0.1 mM with a measurement period of 5 s. Considering that the normal concentration of glucose in serum is between 3.9 and 6.6 mM, the detection limit is sufficiently low. These results show that Fc8m2c is an excellent electron-mediator candidate for sensitive and rapid glucose detection.
UR - http://www.scopus.com/inward/record.url?scp=85148770535&partnerID=8YFLogxK
U2 - 10.1039/d2tb02380f
DO - 10.1039/d2tb02380f
M3 - Article
C2 - 36799139
AN - SCOPUS:85148770535
SN - 2050-7518
VL - 11
SP - 2258
EP - 2265
JO - Journal of Materials Chemistry B
JF - Journal of Materials Chemistry B
IS - 10
ER -