Skip to main navigation Skip to search Skip to main content

Factors affecting accuracy of ventricular volume and ejection fraction measured by gated Tl-201 myocardial perfusion single photon emission computed tomography

  • Moonsun Pai
  • , You Jung Yang
  • , Ki Chun Im
  • , Il Ki Hong
  • , Sung Cheol Yun
  • , Duk Hyun Kang
  • , Jae Kwan Song
  • , Dae Hyuk Moon

Research output: Contribution to journalArticlepeer-review

8 Citations (Scopus)

Abstract

The electrocardiogram-gated single photon emission computed tomography (SPECT) measurement of left ventricular end-diastolic volume, end-systolic volume and ejection fraction may contain substantial errors. We evaluated whether patient-related factors affect the accuracy of left ventricular volume and ejection fraction measured by gated Tl-201 SPECT. A total of 518 patients without perfusion defects on Tl-201 SPECT or coronary artery disease were studied. Left ventricular volume and ejection fraction were measured from echocardiography and adenosine stress/redistribution gated Tl-201 SPECT using commercially available software packages (QGS and 4D-MSPECT). We identified factors affecting the accuracy of gated SPECT via multiple linear regression analysis of the differences between echocardiography and gated SPECT. Gated SPECT analyzed with QGS underestimated end-diastolic and end-systolic volume, and overestimated ejection fraction, but 4D-MSPECT overestimated all those values (P <0.001). Independent variables associated with increasing the difference in end-diastolic volume between echocardiography and gated SPECT were decreasing left ventricular end-diastolic wall thickness, decreasing body surface area, female sex and increasing end-diastolic volume (P<0.001). Those for end-systolic volume were decreasing left ventricular end-systolic wall thickness, female sex, and decreasing end-systolic volume (P <0.001). Increasing end-systolic wall thickness, male sex and decreasing age were independent determinants associated with an increased difference in ejection fraction (P <0.001). Adenosine stress SPECT showed significantly higher end-diastolic and end-systolic volume values and a lower ejection fraction than did redistribution SPECT (P <0.001). Patient-related factors affect the accuracy of left ventricular volume and ejection fraction measured by gated Tl-201 SPECT. Modification of gated SPECT measurements by taking account of these factors would lead to reduce systemic errors.

Original languageEnglish
Pages (from-to)671-681
Number of pages11
JournalInternational Journal of Cardiovascular Imaging
Volume22
Issue number5
DOIs
Publication statusPublished - Oct 2006

Keywords

  • Left ventricular ejection fraction
  • Left ventricular function
  • Single photon emission-computed tomography
  • Thallium-201

Fingerprint

Dive into the research topics of 'Factors affecting accuracy of ventricular volume and ejection fraction measured by gated Tl-201 myocardial perfusion single photon emission computed tomography'. Together they form a unique fingerprint.

Cite this