Abstract
The electrocardiogram-gated single photon emission computed tomography (SPECT) measurement of left ventricular end-diastolic volume, end-systolic volume and ejection fraction may contain substantial errors. We evaluated whether patient-related factors affect the accuracy of left ventricular volume and ejection fraction measured by gated Tl-201 SPECT. A total of 518 patients without perfusion defects on Tl-201 SPECT or coronary artery disease were studied. Left ventricular volume and ejection fraction were measured from echocardiography and adenosine stress/redistribution gated Tl-201 SPECT using commercially available software packages (QGS and 4D-MSPECT). We identified factors affecting the accuracy of gated SPECT via multiple linear regression analysis of the differences between echocardiography and gated SPECT. Gated SPECT analyzed with QGS underestimated end-diastolic and end-systolic volume, and overestimated ejection fraction, but 4D-MSPECT overestimated all those values (P <0.001). Independent variables associated with increasing the difference in end-diastolic volume between echocardiography and gated SPECT were decreasing left ventricular end-diastolic wall thickness, decreasing body surface area, female sex and increasing end-diastolic volume (P<0.001). Those for end-systolic volume were decreasing left ventricular end-systolic wall thickness, female sex, and decreasing end-systolic volume (P <0.001). Increasing end-systolic wall thickness, male sex and decreasing age were independent determinants associated with an increased difference in ejection fraction (P <0.001). Adenosine stress SPECT showed significantly higher end-diastolic and end-systolic volume values and a lower ejection fraction than did redistribution SPECT (P <0.001). Patient-related factors affect the accuracy of left ventricular volume and ejection fraction measured by gated Tl-201 SPECT. Modification of gated SPECT measurements by taking account of these factors would lead to reduce systemic errors.
| Original language | English |
|---|---|
| Pages (from-to) | 671-681 |
| Number of pages | 11 |
| Journal | International Journal of Cardiovascular Imaging |
| Volume | 22 |
| Issue number | 5 |
| DOIs | |
| Publication status | Published - Oct 2006 |
Keywords
- Left ventricular ejection fraction
- Left ventricular function
- Single photon emission-computed tomography
- Thallium-201
Fingerprint
Dive into the research topics of 'Factors affecting accuracy of ventricular volume and ejection fraction measured by gated Tl-201 myocardial perfusion single photon emission computed tomography'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver