Skip to main navigation Skip to search Skip to main content

Iterative multi-channel radio frequency pulse calibration with improving B1 field uniformity in high field MRI

  • Daniel Hernandez
  • , Min Hyoung Cho
  • , Soo Yeol Lee

Research output: Contribution to journalArticlepeer-review

3 Citations (Scopus)

Abstract

Background: In high field MRI capable of multi-channel radio frequency (RF) transmission, B1 shimming is a time-consuming job because conventional B1 shimming techniques require B1 mapping for each channel. After acquiring the complex-numbered B1 field maps, the optimal amplitude and phase of the driving RF pulse are determined for each channel to maximize the B1 field uniformity in conventional B1 shimming. However, time-consuming B1 shimming procedures at the pre-scan may not be tolerated in the clinical imaging in which patient throughput is one of the important factors. Methods: To avoid the time-consuming B1 mapping, the first spin echo and the stimulated echo were repeatedly acquired in the slice-selective stimulated echo sequence without imaging gradients. A cost function of the amplitudes and phases of the driving RF pulse for every channel was defined in a way that the ratio between the spin echo and stimulated echo amplitudes rapidly converged to √ 2. The amplitude and phase of the driving RF pulse were iteratively modified over the repeating RF pulse sequence so that the cost function was minimized. Results: From the finite-difference-time-domain (FDTD) electromagnetic field simulations with a human body model placed in a birdcage coil operating at 3 T, it was observed that the RF pulse calibration with iterative cost function minimization can give improvement of B1 field uniformity as well as flip-angle calibration. The experiments at 3 T also showed improvement of RF field uniformity in the phantom imaging studies. Conclusions: Since the proposed RF pulse calibration is not based on B1 mapping, the RF pulse calibration time could be much shorter than the B1-mapping based methods. The proposed method is expected to be a practical substitute for the B1-mapping-based B1 shimming methods when long pre-scan time is not tolerable.

Original languageEnglish
Article number15
JournalBioMedical Engineering Online
Volume14
Issue number1
DOIs
Publication statusPublished - 21 Feb 2015

Bibliographical note

Publisher Copyright:
© 2015 Hernandez et al.

Keywords

  • B mapping
  • B shimming
  • B uniformity
  • MRI
  • RF pulse calibration

Fingerprint

Dive into the research topics of 'Iterative multi-channel radio frequency pulse calibration with improving B1 field uniformity in high field MRI'. Together they form a unique fingerprint.

Cite this