Validity of the Actigraph-GT9X accelerometer for measuring steps and energy expenditures in heart failure patients

  • Jisu Kim
  • , Jonathan Kenyon
  • , Hayley Billingsley
  • , Natalie Bohmke
  • , Syed Imran Ahmed
  • , Hannah Salmons
  • , Jung Min Lee
  • , Danielle Kirkman
  • , Salvatore Carbone
  • , Youngdeok Kim

Research output: Contribution to journalArticlepeer-review

4 Citations (Scopus)

Abstract

Introduction The ActiGraph (AG) accelerometer is widely used to assess physical activity (PA) in heart failure (HF) patients. However, the validity of the AG in this population remains unexplored. Objective Therefore, this study examined the criterion validity of the AG-GT9X for measuring step counts (SC) and energy expenditure (EE) among HF patients. Methods 16 patients with HF with preserved ejection fraction (mean age = 60.3±12.1yrs) completed a total of 41 symptom-limited cardiopulmonary exercise tests on a treadmill across multiple time points (median (IQR) = 2.5 (1.5–3.5)). All participants wore the AG (model: GT9X) on both the right ankle and waist locations during the test. Manually counted steps and indirect calorimetry-derived EE served as criterion measures. AG-derived EE was estimated using six different prediction equations previously developed for waist-worn AG. AG-derived measurements were compared with criterion measurements by calculating correlation coefficients, equivalence tests with two one-sided tests, mean absolute percentage error (MAPE), percentage bias, and Bland-Altman plots using mixed models to account for the nested nature of repeated measures within subjects. Results Ankle-worn AG-SC was significantly equivalent to the criterion (p < .05) and had lower MAPE (<10%) compared to the waist location, regardless of PA intensity level. Sasaki-EE was significantly equivalent to the criterion (p < .05), with the lowest percentage bias overall (0.7%). Conclusions The ankle-worn AG-SC and Sasaki-EE showed better accuracy among HF patients in laboratory settings. Further research is warranted to cross-validate the results in different settings.

Original languageEnglish
Article numbere0315575
JournalPLoS ONE
Volume19
Issue number12 December
DOIs
Publication statusPublished - Dec 2024

Bibliographical note

Publisher Copyright:
© 2024 Kim et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Fingerprint

Dive into the research topics of 'Validity of the Actigraph-GT9X accelerometer for measuring steps and energy expenditures in heart failure patients'. Together they form a unique fingerprint.

Cite this